Menu
Your Cart

Osmosis Direct Flow CELPORAGUA

Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
Pre-Order
Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
Osmosis Direct Flow CELPORAGUA
0.00€
Ex Tax: 0.00€
  • Stock: Pre-Order
  • Model: CEL APORAGUA
  • Weight: 12.00kg
  • Dimensions: 465.00mm x 160.00mm x 385.00mm

DIRECT FLOW OSMOSIS CEL APORAGUA


Advanced reverse osmosis equipment

Direct flow 4 stages of filtration

600 GPD capacity

Fill your glass with water in just 12 seconds

Ultra compact and adaptable to any space


  • Capacity 600 GPD (2,280 lpd)
  • Compact size
  • Double information system in equipment and tap
  • Conversion ratio: 60%
  • 1.5 / 2 LPM High Production
  • Filter change notice
  • Membrane change notice
  • Direct Flow. Equipment without deposit
  • Filter composed of 4 filtration stages
  • Integrated hydraulic circuit
  • 2: 1.5 Ratio of produced water to dispensed water
  • Higher flow of water dispensed
  • Filter change in just 2 minutes
  • Electronic leak sensor
  • Easy maintenance equipment
  • 2-way special tap
  • Smart membrane car wash


FILTER COMPOSED OF 4 FILTRATION STAGES:

PP: Removal of large particles, sediments, rust

CB: Accuracy: 5-10 microns. Removes 85% of chlorine

RO: Removal of heavy metals and bacteria

99.9% removal of heavy metals, chlorine, bacteria, rust, organic matter, etc.


QUICK AND EASY FILTER CHANGE:

In just 3 seconds, with a simple twist and without having to move the equipment, quickly remove the exhausted filter and replace it with the new one so that your equipment works 100% again.


MEMBRANE MRO:
600 GPD membrane.
Maximum production and minimum rejection.


VERY DURABLE FILTERS:
Open the door to savings.
RO 600 GPD High Production Membrane
CF. Carbon block prefilter with 5 micron polypropylene filtration.


INTELLIGENT DISPLAY:
The front light display indicates the useful life and the recommended change of the filters and the membrane.


A 100% ENVIRONMENTALLY RESPECTFUL TEAM:
2 liters produced = only 1.5 liter of rejection
(A standard 5-stage reverse osmosis equipment usually rejects about 9-10 liters of water for every liter produced)
Equipment without deposit. Guarantees osmotized water instantly directly from your tap.


2-WAY TAP:
Choose the water that suits you best: filtered or osmosis.


MEMBRANE SELF-WASH:
Built-in program.
Prevents clogging of the membrane and lengthens its useful life.
Ensures water of high quality and better taste.


INTEGRATED CIRCUIT:
Less leakage
Less welds
Stronger sealing
Easier and safer to use


HYDRAULIC, ELECTRICAL AND ELECTRONIC CONNECTIONS:
  1. Data interface
  2. 1/4 "drain
  3. 1/4 "tap
  4. 3/8 "water inlet
  5. Electrical power supply
  6. Possibility of filtered water



 TECHNICAL CHARACTERISTICS:

Pressure (max.-min.) : 4-1 bar (400-100 kPa)

Temperature (max.-min.) : 38-5ºC

TDS (max.) : 1500 ppm

Hardness (max.) : 20 ºHF

Weight : 12 kg

Electrical power supply : 24 VDC 5A 95W

Adapter : 100 - 240 VAC 60 - 60 Hz

Production (max.) : 1,5 - 2 LPM

Recovery : >= 60%



FILTER SPECIFICATIONS:

FILTERCF - PREFILTER CARBÓN + PPMRO - MEMBRANE RO

MEDIUMPPCBRO 600 GPD
FUNCTIONALITY
Removal of large particles, sediments, rust

Removal of large particles, sediments, rust.

Elimination of color, odor, improvement of taste. Removal of chlorine, carbon, tetrachlorine, methane.

Elimination of heavy metals, microorganisms, bacteria, pesticides and antibiotics. Desalination:> = 90%
PRECISION10 microns5 - 10 microns0.0001 microns
TOTAL CAPACITY
3 lpd3 lpd1.6 lpd
RECOMMENDED CHANGE
12 months12 months36 months



AUTOMATIC FLUSHING FUNCTIONALITIES:



FUNCTION
ACTIONS
STATUS OF THE LIGHTS
1. Functional wash for the first use
The equipment will wash the RO membrane for 5 min. The tap must then be turned on for 30 min.
During washing, the water quality light is flashing red at 1Hz. After 6 min., The water quality light will return to the live measurement state.
2. Washing at the start of the equipment
Whenever it starts up, the equipment will wash the RO membrane for 20 seconds. If the user opens the tap, the equipment will stop washing and go into normal mode.
During washing, the water quality light is flashing red at 1Hz. After 6 min., The water quality light will return to the live measurement state.
3. Washing when accumulating operating time
Every time the accumulated working time reaches 2 hours, the equipment will wash the RO membrane for 20 seconds. If the user opens the tap, the equipment will stop washing and go into normal mode.
During washing, the water quality light is flashing red at 1Hz. After 6 min., The water quality light will return to the live measurement state.
4. Daily washing
When the equipment has not been working for 24 hours, it will wash the membrane for 20 seconds when it starts up again. If the user opens the tap, the equipment will stop washing and go into normal mode.
During washing, the water quality light is flashing red at 1Hz. After 6 min., The water quality light will return to the live measurement state.
5. Washing after filter change

CF: when changing the pre-filter and resetting its usage counter, the equipment will start a wash of the CF filter and the RO membrane for 5 min.

RO: when changing the RO membrane and resetting its usage counter, it must be washed by turning on the tap for 30 minutes.

CB: when changing the CB post-filter and resetting its usage counter, it must be washed by opening the tap for 15 min. If all filters are changed and reset at the same time, the equipment will wash the CF filter and RO membrane for 5 min. The tap should then be turned on for 30 min. to wash the CB post filter.

When the RO membrane is being washed, the water quality light shows red and flashing at 1Hz.

When any other filter is washed, the water quality light displays real-time water quality data and flashes at 1Hz.




performance
Deposit It does not have a tank, so you have no water limit and save space
Liters day / hour 1.5 / 2 Liters Per Minute
Technical characteristics
Electrical power supply 24 VDC 5A 95W
Benefits
Filter cleaning / change notice Filter and membrane change
leak sensor electronic
Smart membrane car wash lengthens its useful life and its performance
Touch digital display Intelligent luminous display - front warning of the status of filters
Plumbing
Maximun working pressure 4 bar (400 kPa)
Minimum working pressure 1 bar (100 kPa)
Water production
Continuous production 1.5 / 2 Liters Per Minute
Water treatment system
Ecological no deposit and little rejection
Osmosis type Ecological direct flow without reservoir
Stages of reverse osmosis 4 stages: PP, CB, RO
Weight
Weight 12 Kg
Technical
Adapter 100 - 240 VAC 60 - 60 Hz
Maximum hardness 20 ºHF
Recovery >= 60%
TDS (maximum) 1500 ppm
Work temperature Maximum 38 ºC Minimum 5 ºC